KR SERIES

PROPERTIES

Resistance to: Ultraviolet rays, ozone, mineral oils, fuels, salts, alkalis, alcohol, hydrocarbons, ketones, ether, termites and radioactive rays*
Flame resistance: UL94 5VA (IEC 60695-11-20)
UL94 V-0 (IEC 60695-11-10)
IEC 61914 following IEC 60695-11-5
Classification following DIN 5510,
part 2 Flammability class: S3
Thermal expansion: 0.01% per 10°C temperature increase
Tensile strength: 120 N/mm2
Flexural strength: 210 N/mm2

TEMPERATURE RANGE

Ambient temperature: down to -60°C*
Continuous operation: up to 120°C
Permitted short-term heating: up to 220°C
Operation life: more than 40 years of maintenance- and failure-free operation

 

MATERIAL

High-grade polyamide, fibreglass-reinforced, coloured black, with special UV protection, fully recyclable, self-extinguishing, low-smoke, zero halogen (LSZH), silicone free, non-toxic, non-corrosive, non-metallic, non-magnetic

Applications:

Fastening of single- and multi-core cables for high short circuit fores. Universal application indoors and outdoors between -60°C and +120°C. Fastening in single, parallel and bundled formation.

Outer diameter of cables:

70 mm to 250 mm

Dynamic resistance to short circuits:

30.000 N

Tightening Torque for fixing material:

Top part: 8 Nm**
Bottom part: 20 Nm

Dimensions in mm

Type DØ DØ++ L L1 B b I H1 H2 h a dØ Screw thread
KR 75/100 75-100 70-95 180 172 77 44 150 71-97 109-134 52 17 14 M12
KR 100/130 100-130 95-125 210 197 97 54 175 99-129 140-170 69 20 14 M12
KR130/160 130-160 125-155 250 213 97 54 210 116-146 176-206 87 23 18 M16
KR 160/200 160-200 155-195 290 258 120 60 250 172-212 230-270 113 35 18 M16
KR 200/250 200-250 195-245 340 300 120 61 300 190-240 280-330 130 40 18 M16
DØ: Outer cable diameter
DØ++: ~ with one Elastic Inlay
* For more information please contact îd-Technik.
** Please contact îd-Technik for trailing cables (EPDM, rubber, etc.).

NORM IEC 61914

îd-Technik Cable Clamps have been type-tested by accredited test institutes to the international standard IEC 61914.

Legal compliance

  • Directive 2015/863/EU (RoHS)
  • Regulation (EC) No. 1907/2006 (REACH regulation)

Constructional features

  • Particularly high dynamic and mechanical strength and heat resistance due to special fibreglass-reinforced polyamide
  • Safe restraint of dynamic forces of high short circuit currents, without damage to the cables, also for multiple short circuits
  • Type-tested to IEC 61914 – cable cleats for electrical installations - reports from accredited institutes regarding dynamic short circuit currents, the fire-resistance of the material, and mechanical properties of the Cable Clamps are available
  • Very low surface pressure on cables due to Cable Clamps’ large contact area
  • Unrestricted application both indoor and outdoor in extreme climates such as deserts, tropics, high altitudes, arctic climate, coastal salt fogs, flooding and ozone due to special resistance to ageing, ultraviolet rays and ozone
  • Easy to mount without special instruments and maintenance-free
  • Fastening of Cable Clamps adaptable to all local conditions

Type-Tests to IEC 61914 on KR Series Clamps approved results in highest classification

Classification Test conditions Approved results Paragraph
Material: non-metallic high-grade polyamide 6.1.2
Operating temperature -60°C / +120°C passed 6.2
Resistance to impact -60°C, 5 kg at 400 mm height very heavy 6.3.5
Lateral load test (N)
– in x-direction
– in y-direction
At +120°C 18.000 N
15.000 N
6.4.1
Axial load test (N)
– with Elastic Inlays
+120°C 1.500 N 6.4.2
Resistance to electrodynamic forces [N]
suited to withstand multiple short circuits
Peak short circuit current: 181 kA
Cable Clamp spacing: 1,10 m
30.000 N 6.4.4
UV-resistance high passed 6.5.1
Flame propagation 1 x 30s, needle flame method passed 10.1 (IEC 60695-11-5)
2 x 10s, 50 W test flame method V-0 UL 94 V (IEC 60695-11-10)
5 x 5s, 500 W test flame method 5VA UL 94 5V (IEC 60695-11-20)
3 min S3 DIN 5510

Use of Elastic Inlays:

  • As a cushion for elastic adjustment of cable diameter changes due to operational load changes and/or changes in the ambient temperature
  • Precise cable fixation and absorption of weight forces, primarily on cables installed along inclines or attached to vertical surfaces where restraint of axial movement is essential
  • Compensation of vibrations, e.g. in wind turbines, without reducing retention forces
  • Expansion of the Clamp’s clamping area, for cables with a smaller outer diameter
  • Elastic Inlay 100 mm x 100 mm for KR 75/100, KR 100/130
  • Elastic Inlay 150 mm x 140 mm for KR 130/160, KR 160/200, KR 200/250