Assembly instructions for K-Tower Series

Selection of fastening material:

Material and corrosion resistance:
The choice of material for the fasteners is dependent on the installation environment and operating conditions (e.g. galvanised, stainless steel, etc.), strength grade 4.8 - 8.8

Type of screw:
depends on the substructure (e.g. hexagon screws, T-head screws, etc.); not included in delivery

Fastener diameter:
depends on the Cable Clamp (table: metric screw thread [M])

Fastener Length:
depends on the number of stacked Cable Clamps, the cable outer diameter and type of substructure

Application with Elastic Inlays:
on-site fixing with any form of adhesive (e.g. glue, silicone or paste) will void the warranty immediately

List of individual components K-Tower Series:

Cable Clamp typeOuter diameter of cableMetric screw thread (M)Recommended length of thread*
K 26/3833-38 mmM10/12135 mm + x
K 36/5242-52 mmM10/12165 mm + x
K 50/7551-75 mmM10/12205 mm + x
K 66/9074-90 mmM12235 mm + x

* For maximum permited outer cable diameter (can be reduced accordingly for smaller diameters)
x corresponds to the height of the substructur.

List of individual components Triple Tower:

Cable Clamp typeOuter diameter of cableMetric screw thread (M)Recommended length of thread*
K 26/3833-38 mmM10/12185 mm + x
K 36/5242-52 mmM10/12230 mm +x
K 50/7551-75 mmM10/12300 mm + x

* For maximum permited outer cable diameter (can be reduced accordingly for smaller diameters)
x corresponds to the height of the substructur.

Alternating, tighten nuts with an appropriate torque wrench. Do not use self-securing/self-locking nuts, this prohibits a defined tightening torque.

Only flat washers may be used. No spring or snap rings!

It is essential to respect the specified tightening torques, especially for the upper part, to guarantee perfect and reliable functioning of the cable installation for the long-term.**

** Contact îd-Technik for trailing cables (EPDM, rubber, etc.), please.